Electrical drawings in.Reviewed tag data out.

PLC Automator reads your electrical schematics and drafts the tag database, documentation and controls code. A qualified engineer reviews the flagged rows and approves the output.

Schematic Set.pdfPage 4, digital input cardReading row 1 of 8
PLC digital input wiring schematic: eight field circuits wired through CB22 terminal blocks to a digital input module, with each field description marked as it is readPLC I/OPLC MODULE6ES7214-1AE30DIGITAL INPUTSM24V-PUMP #1 AUTO STATUSCB22H O A0/0I:0.0PUMP #1 RUN STATUSCB22P1-RUN0/1I:0.1PUMP #1 FAULT STATUSCB22P1-FAULT0/2I:0.2WET WELL LOW FLOATCB22WET WELL0/3I:0.3PUMP #2 AUTO STATUSCB22H O A0/4I:0.4PUMP #2 RUN STATUSCB22P2-RUN0/5I:0.5PUMP #2 FAULT STATUSCB22P2-FAULT0/6I:0.6SPARECB22SPARE0/7I:0.7
Title
Pump station digital inputs
Drawing
04, sheet 4 of 6
Checked
Not yet checked
Tags read from drawing 04
TagDescriptionAddress
P1_AUTOPump #1 Auto StatusI:0.0
P1_RSPump #1 Run StatusI:0.1
P1_FLTPump #1 Fault StatusI:0.2
WW_LO_FLOATWet Well Low FloatI:0.3
P2_AUTOPump #2 Auto StatusI:0.4
P2_RSPump #2 Run StatusI:0.5
P2_FLTPump #2 Fault StatusI:0.6
SPARE_DI_0_7Needs review: Visible row is spare/blank without field-side textI:0.7
1 row flagged for engineer reviewExport for Schneider Electric
PDF schematics in
Upload the drawing set you already have.
Vendor tag files out
XBD and XML packs, formatted for your PLC software.
Every tag traced
Each record links back to its place on the drawing.
Nothing locked in
The drawings and the outputs stay yours.
IO_List_rev3_FINAL(2).xlsx
A2fx
RowABC
1TagDescriptionAddress
2   
3   
4   
5   
6   
7   
8   

Wrong tag: P1_FTL should be P1_FLT. Nobody notices until testing.

Most projects still start with someone typing the tag list by hand.

Typed line by line
Tag lists, alarm lists and I/O schedules are copied from the drawings into spreadsheets by hand.
Found during testing
A typing error in the tag list shows up at factory acceptance testing or on site, when it is slow and costly to fix.

More done by the same engineering team

It does not replace engineering judgement. It removes repeated data transcription, so engineers spend their time on review, design and commissioning.

Questions about fit? We are a small team. We answer every email personally, usually within one business day.

  • For the integrator

    More delivery capacity, better repeatability and stronger fixed-price and unit-rate execution.

  • For the engineer

    Less repetitive spreadsheet work. More time for review, design, testing, commissioning and training.

  • For the end client

    Faster, traceable and consistent engineering data, with fewer errors to fix during FAT and commissioning.

From drawing to vendor export

  1. 1

    Import the drawing set

    Choose the PDF and the pages that hold the I/O.

  2. 2

    Extract the tags

    Tag names, descriptions and addresses are read from each line of the drawing.

  3. 3

    Apply your conventions

    Alarms, bypasses and delays are generated to your naming rules.

  4. 4

    Export for your PLC

    Produce a data pack for Schneider Electric, Allen-Bradley or Siemens.

Drawing 04 · Digital input card24V DC
PLC digital input wiring schematic: eight field circuits wired through CB22 terminal blocks to a digital input module, with each field description marked as it is readPLC I/OPLC MODULE6ES7214-1AE30DIGITAL INPUTSM24V-PUMP #1 AUTO STATUSCB22H O A0/0I:0.0PUMP #1 RUN STATUSCB22P1-RUN0/1I:0.1PUMP #1 FAULT STATUSCB22P1-FAULT0/2I:0.2WET WELL LOW FLOATCB22WET WELL0/3I:0.3PUMP #2 AUTO STATUSCB22H O A0/4I:0.4PUMP #2 RUN STATUSCB22P2-RUN0/5I:0.5PUMP #2 FAULT STATUSCB22P2-FAULT0/6I:0.6SPARECB22SPARE0/7I:0.7

Start where the repeated work is

Tag data packs
PLC and HMI tag databases with your naming rules, descriptions and source references, exported for your vendor environment.
Documentation inputs
Test sheets and verification documents, so the commissioning team arrives ready.
Panel and SCADA mapping
Address lists and communication registers aligned for screen configuration, such as C-more.
Logic and alarm blocks
Standard code routines and customer-approved alarm logic, with as much or as little automation as the engineer chooses.

PLC Automator does not deploy PLC code, connect to live OT systems or make unreviewed safety or process decisions.

Your engineering data stays yours

For each controlled pilot, we agree the permitted drawings, processing route, authorised users and retention period before work begins. We process only what the agreed workflow needs.

Pilot material is not used for demonstrations or other development without your written permission.

  1. Your drawings

    Retention and access are agreed before any work begins.

  2. Private model

    Processing runs on privately hosted models in our AWS environment. Pilot material is never used to train AI models.

  3. Your data pack

    You keep all rights to your drawings and outputs. No live OT connection, no code deployment and no unreviewed decisions.

Prove it on one agreed drawing set

Start with one drawing type and a controlled output. We measure preparation time, review effort, exceptions and how useful the output is before proposing anything broader.